Chapter 5 Operating Instructions
CLV 490 Bar Code Scanner
5-20
©
SICK AG · Division Auto Ident · Germany · All rights reserved 8 008 796/0000/25-06-2002
Electrical installation
Connect the outputs as shown in
Fig. 5-6.
"
Note If the "Device Ready" function is chosen, the CLV outputs a static pulse in Reading mode.
For connecting the host interface via the AMV/S 60 Connection Module, see the Operating
Instructions for the "
AMV/S 60 Connection Module
" (no. 8 008 296).
Tip
The output function, pulse duration (timer), and polarity of the signals can be changed on
the D
EVICE
C
ONFIGURATION
tab in the "CLV-Setup" program.
Click the E
DIT
R
ESULT
O
UTPUTS
button and enter the values in the dialog box displayed.
Recommendation To check the switching functions using a high-impedance digital voltmeter, connect a
load to the outputs to prevent incorrect voltage values/switching statuses from being
displayed.
Fig. 5-6: Connections of the "Result 1 ... Result 4" switching outputs
V
S
= +18 ... +30 V DC for CLV without heater,
24 V DC +20 %/–10 % for CLV with heater
Pin and terminal assignment
for "Result X" see
Table 5-22
Pulse duration
depending
on setting:
10 ms ... 900 ms
100 ms ... 9 900 ms
00: static
(to the end of next
reading pulse)
GND
Result X
Fuse
Result XY
GND
R
L
V
S
5
Logic
Temperature
sensor
AMV 60-011/
AMS 60-012, -013
Terminal assignment
Z
T.35
Output
"Result X"
CLV "I/O" connection
Pin Y
AMV/S 60
Terminal Z
Result 1 Pin 4 T. 31
Result 2 Pin 8 T. 32
Result 3 Pin 10 T. 33
Result 4 Pin 15 T. 34
Table 5-22: Pin and terminal assignment for "Result 1 ... Result 4" switching outputs
Switching mode PNP-switching with respect to the supply voltage V
S
Properties The current in the event of a short-circuit is limited to 0.7 A
Function
assignment
(default)
"Result 1": Device Ready (static), polarity: not inverted
"Result 2": Good Ready, polarity: not inverted
"Result 3": No Ready, polarity: not inverted
"Result 4": Match 1, polarity: not inverted
Pulse duration: 100 ms
Electrical values
0 V
V
O
30 V Guaranteed: V
O
V
S
1.3 V with I
0
100 mA
I
0
100 mA
Table 5-23: Characteristic data of the "Result 1 ... Result 4" switching outputs