SICK CLV490 Instructions d'exploitation Page 100

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 214
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 99
Chapter 6 Operating Instructions
CLV 490 Bar Code Scanner
6-34
©
SICK AG · Division Auto Ident · Germany · All rights reserved 8 008 796/0000/25-06-2002
Operation
6.7 Switching off the CLV
1. If the parameter set was modified in CLV-Setup or was only stored temporarily in CLV
via a download, the parameter set must be stored permanently in the CLV by choosing
the P
ERMANENT
storage option.
2. Save the parameter set as a configuration file "*.scl" in CLV-Setup.
3. Switch off the power supply of the AMV/S 60 or unplug both of the CLV’s connecting
cables from the connection module.
The last parameter set stored permanently in the CLV remains valid.
We recommend that you print out the configuration file in order to archive the parameter set.
1. Click in the toolbar.
The P
RINT
FILE
dialog box is then displayed.
2. Enter a comment in the input field in order to assign the printout to the CLV.
Confirm your entry with OK.
The P
RINT
dialog box for configuring the printer is then displayed.
3. Make the necessary entries in the dialog box and confirm these.
CLV-Setup prints out the current configuration file in the form of a table.
Vue de la page 99
1 2 ... 95 96 97 98 99 100 101 102 103 104 105 ... 213 214

Commentaires sur ces manuels

Pas de commentaire