Operating Instructions Chapter 4
CLV 490 Bar Code Scanner
8 008 796/0000/25-06-2002
©
SICK AG · Division Auto Ident · Germany · All rights reserved
4-1
Installation
4 Installation
4.1 Installation sequence
Change the language version of the laser warning label (if necessary)
Select the mounting location for the CLV
Align the CLV with the bar code
Mount the CLV
Mount the AMV/S 60 Connection Module
Connect the CLV to the AMV/S 60 Connection Module
Adjust the CLV so that it is in line with the bar code
Mount the reading pulse sensor for external triggering the reading pulse
Option with event-controlled dynamic focus control:
mount the sensors for detecting the object distance
4.2 Preparations
4.2.1 Required components
CLV Bar Code Scanner
4.2.2 Required accessories
SICK mounting bracket for the CLV:
depending on the order, angle bracket no. 2 013 824, articulated bracket
no. 2 018 435, or quick-clamping device no. 2 016 110 with securing material for
the CLV
– or –
Alternatively, if the bracket is supplied by the user
Stable mounting device that allows the alignment of the CLV to be varied in the x and
y axes. The weight of the CLV (line scanner) is 1.5 kg and 2.2 kg as a line scanner
with oscillating mirror.
2 screws M 6 for the CLV. The screw length depends on the wall thickness of the
bracket used. Depth of engagement in CLV max. 7 mm from housing surface.
AMV/S 60 Connection Module (not included in the scope of supply of the CLV)
Reading pulse sensor for external reading pulse triggering, e. g. photoelectric reflex
switch/ photoelectric proximity switch (not included in the scope of supply of the CLV)
Option with event-controlled dynamic focus control: sensors for detecting the object
distance, e. g. photoelectric reflex switches/photoelectric proximity switches (not
included in the scope of supply of the CLV)
4.2.3 Required auxiliary parts
2 screws M 6 for securing the SICK mounting bracket to the base. The screw length
depends on the wall thickness of the base.
Set of laser warning labels (if necessary)
Tool
Measuring tape (up to 3 000 mm)
Protractor