Operating Instructions Chapter 5
CLV 490 Bar Code Scanner
8 008 796/0000/25-06-2002
©
SICK AG · Division Auto Ident · Germany · All rights reserved
5-13
Electrical installation
5.5 Electrical installation procedure
5.5.1 Individual steps
Connect the power supply
Connect the host interface
Connect the PC (connect the terminal interface)
Connect the "Sensor" and "IN 0 ... IN 4" switching inputs
Connect the "Result 1 ... Result 4" switching outputs
5.5.2 Tools
Tool
Digital measuring device (current/voltage measurement)
5.5.3 Connecting the supply voltage
a) SICK AMV/S and BMV 10 Connection Modules
If the CLV is powered via the SICK Connection Modules, the supply voltage does not have
to be wired separately.
Connecting the CLV without external parameter memory:
1. Make sure that the power supply to the Connection Module is switched off.
2. Connect the "Host/Term" and "I/O" connections on the CLV to the corresponding con-
nections on the Connection Module using two cables no. 2 020 302 and secure them
tightly on both sides.
Connecting the CLV with external parameter memory:
1. Mount the connector cover with the external parameter memory no. 2 020 307 on the
"Host/Term" and "I/O" connections of the CLV and screw it tightly into position.
2. Connect the two free plug connections on the cables to the corresponding connections
on the Connection Module and secure them tightly.
The data and function interfaces of the CLV are connected to the Connection Module.
b) Power supply via non-SICK Power pack
Connecting the CLV without external parameter memory:
1. Connect the cable socket on cable no. 2 020 303 on the "Host/Term" connection and
screw it tightly into position.
2. Connect the cable plug on the cable no. 2 020 264 to the "I/O" connection and screw
it tightly into position.
3. Connect the power supply to the red wire (Pin 1, V
S
) and blue wire (Pin 5, GND) on cable
no. 2 020 303.
See also Table5-10, Page5-9
Connecting the CLV with external parameter memory:
1. Connect the "Host/Term" and "I/O" connections on the CLV to the corresponding con-
nections on the Connection Module using two cables no. 2 020 981 and secure them
tightly on both sides.
2. Connect the power supply to the red/pink wire (Pin 1, VS) and the blue/grey-brown wire
(Pin 5, GND) of cable 1. See also
Table5-12, Page5-11.
The CLV is connected to the supply voltage.