SICK CLV490 Instructions d'exploitation Page 196

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 214
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 195
Chapter 10 Operating Instructions
CLV 490 Bar Code Scanner
10-74
©
SICK AG · Division Auto Ident · Germany · All rights reserved 8 008 796/0000/25-06-2002
Appendix
b) CLV with heater
Temperature range of connection material:
Stationary: –50 ... +70
°
C; moving: –40 ... +70
°
C
Note Other cable lengths/types for CLVs with heater available on request.
10.13.5 Plug-in connections
10.13.6 Reading pulse generators
The SICK catalog
"SENSICK Sensors for Automation"
(no. 8 006 530) contains a large sel-
ection of photoelectric switches and photoelectric proximity switches as well as the asso-
ciated accessories (brackets, connection cables)
10.13.7 Network controller
Order No. Description Wires Length Connection
2 021 689 Connector cover with with parameter memory (EEPROM),
enclosure rating IP 65, with 2 connection cables, each
8 mm,
shielded, with 15-pin D Sub HD socket and 15-pin D Sub HD plug
Required: 1 per CLV
each 15 x
0.14 mm
2
3 m CLV 490 to
AMV 100/200
2 021 298 2 x connector cover, enclosure rating IP 65,
with 2 connection cables, each
6.7 mm, shielded.
Required: 1 per CLV
each 13 x
0.14 mm
2
+
2x 0.75mm
2
3 m CLV 490 to
AMV 100/200
2 021 267 Connector cover, enclosure rating IP 65,
with 2 connection cables, each
6.7 mm, shielded,
two open ends (stripped).
Required: 1 per CLV
1 x 18 x
0.14 mm
2
+
1 x 2 x 0.75 mm
2
3 m CLV 490 to
Host, sensors,
PLC and non-
Sick Power pack
Table 10-15: Accessories: cables and connector covers for the CLV with heater
Order No. Description
6 009 438 D Sub connector housing (metal) for 9-pin or 15-pin HD inserts
6 007 335 D Sub connector insert, 9-pin socket connector
6 010 019 D Sub connector insert, 15-pin HD socket connector
6 010 020 D Sub connector insert, 15-pin HD pin connector
Table 10-16: Accessories: plug-in connections
Order No. Type Description
On request CLX 200 Network controller with LCD, touch-sensitive keypad, integrated power pack and 9-pin D-Sub
connections for network, host and terminal, enclosure rating IP 31
Table 10-17: Accessories: network controller
Vue de la page 195
1 2 ... 191 192 193 194 195 196 197 198 199 200 201 ... 213 214

Commentaires sur ces manuels

Pas de commentaire