SICK CLV490 Instructions d'exploitation Page 141

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 214
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 140
Operating Instructions Chapter 10
CLV 490 Bar Code Scanner
8 008 796/0000/25-06-2002
©
SICK AG · Division Auto Ident · Germany · All rights reserved
10-19
Appendix
Fig. 10-17: CLV 490-2010/-2011 (High density): Min. and Max. reading distance (measured radially) as a function of the focus
position at a resolution of 0.35 mm and an aperture angle of
α
=56
°
1800
1900
2000
2100
2200
1700
1600
1500
500 700 900 1100 1300 1500 1700 1900 2100
1400
1300
1200
1100
1000
900
800
700
600
500
400
Line scanner (front reading window): CLV 490-2010/-2011
Reading distance [mm]
max. reading distance
Resolution: 0.35 mm
Aperture angle: 56
°
Focus position [mm]
min. reading distance
Reading conditions:
see Table 10-1, Page 10-1
Characteristics field scanning frequency/
reading distance: see Table 10-18, Page 10-20