Vue de la page 34
Operating Instructions Chapter 3
CLV490 Bar Code Scanner
8009993/RA61/2007-07-20 © SICK AG · Division Auto Ident · Germany · All rights reserved 3-13
Product description
b) External parameter memory CMC400 in the CDB420/CDM490 Connection
Module
The function of the "Device Ready" and "Read Result" LEDs on the CLV490 when using the
CMC400 as well as the remedy for error messages are described in the CMC400 Operating
Instructions (order no. 8010002, German/English).
See also Chapter 10.3.1 Function of the external parameter memory, Page 10-35.
Start
continued
Read Result
continued
Green Start option: START WITH EXTERNAL PARAMETERS (default)
Blinks for approx. 10 s together with "Device Ready"
LED
1)
(see above) or
Blinks constantly together with the "Device Ready" LED
2)
(see above)
Start option: S
TART WITH COPY INTERN -> EXTERN
Blinks alternately with "Device Ready" LED for approx. 10 s (see above) or
Blinks constantly together with the "Device Ready" LED
2)
(see above)
Reading mode Device Ready Green Lights up constantly
Extinguishes with new operating mode/function
Sensor Green Lights up if reading diode active
(The laser diode is activated/deactivated by the reading pulse)
Lights up constantly in Free-running mode, since the laser diode is constantly
active
Read Result Green LED is linked to the "Result 2" output and indicates the selected result status for the
defined pulse duration of the output.
Lights up after a successful read (Good Read)
Lights up if the match code comparison is active, the bar code read matches the
specified match code(s) and the corresponding result output is selected for the
"Result 2" output
Data Yellow Flickers when the CLV490 transmits data to the host over the host interface
Percentage Sensor Green Lights up constantly, since Free-running mode is active
evaluation Read Result Green Behavior dependent on the reading quality:
Extinguishes if reading rate < 30 %
Blinks twice a second if reading rate 30 % to 70 %
Blinks five times a second if reading rate 70 % to 90 %
Lights up constantly if reading rate > 90 %
Adjusting mode Sensor Green Lights up constantly, since Free-running mode is active
Show RA-limits Sensor Green Blinks bright/dark alternately, in the frequency with which the scan line is (partially)
masked out
1) We recommend that you check the parameter set manually, e. g. by printing out the entire configuration. For troubleshooting, see also Chapter 8.3.2 LED error messages
for the external parameter memory (connector cover), Page 8-3
2) Stops blinking when you switch from Reading mode to Parameterization mode
Operating mode LED Display Function
Table 3-3: Meaning of LEDs: CLV490 with external parameter memory in the connector cover (contd.)