Operating Instructions Chapter 6
CLV490 Bar Code Scanner
8009993/RA61/2007-07-20 © SICK AG · Division Auto Ident · Germany · All rights reserved 6-53
Operation
6.5.8 Displaying and editing operating data
This function enables statistical operating data, which the CLV490 maintains in the form of
counters during the reading procedure, to be displayed and reset.
The CLV490 does not output a reading result in this mode.
1. Click in the tool bar.
The CLV490 cancels the Reading mode and the "Device Ready" LED is extinguished.
The O
PERATING DATA dialog box appears (Fig. 6-17).
2. After checking/resetting the desired counters, click OK to confirm any changes made.
The CLV490 then returns to the Reading mode and the "Device Ready" LED lights up.
Fig. 6-17: CLV-Setup: "Operating Data" dialog box